Estudio Descriptivo: Dosis Efectiva de Radiación en Angiotomografías Coronarias Multidetector de Enero del 2013 a Diciembre del 2015 en el Hospital de Especialidades José Carrasco Arteaga

Autores/as

  • Carlos Ismael Ortega Díaz Hospital de Especialidades José Carrasco Arteaga
  • Juan Felipe Vintimilla Garate Hospital de Especialidades José Carrasco Arteaga
  • Arturo Ricardo Quizhpe Rivera Hospital de Especialidades José Carrasco Arteaga
  • Winston Xavier Moreira Vera Hospital de Especialidades José Carrasco Arteaga
  • María José García Zambrano Hospital de Especialidades José Carrasco Arteaga
  • Byron Rafael Coronel Cárdenas Hospital de Especialidades José Carrasco Arteaga
  • Priscila Raquel Criollo Esquivel Ministerio de Salud Pública del Ecuador
  • Xavier Miguel Salazar Alvarado Hospital Monte Sinaí

Palabras clave:

ENFERMEDAD CORONARIA, FACTORES DE RIESGO, ANGIOGRAFÍA CORONARIA, CORONARY DISEASE, RISK FACTORS, CORONARY ANGIOGRAPHY

Resumen

INTRODUCCIÓN: La coronariografia convencional sigue siendo el patrón de referencia para cuantificar y guiar el tratamiento en la enfermedad coronaria sin embargo con la introducción de la angiotomografia coronaria multidetector en la valoración de placas ateromatosas coronarias y con esto la exposición a la radiación ha permanecido como área de constante preocupación. En la práctica diaria se recomienda basarse en lo que se conoce como As Low As Reasonably Achievable que significa optimizar la radiación sin perjuicio de la calidad del estudio.

MÉTODOS: Se trata de un estudio descriptivo retrospectivo en el Hospital de Especialidades José Carrasco Arteaga de Cuenca – Ecuador, durante el periodo de tiempo comprendido entre el 01 enero del 2013 y 31 diciembre del 2015. Para este estudio se incluyeron todos los pacientes a quienes se les realizo angiotomografia coronaria multidetector, se recolectaron los datos clínicos y la dosis efectiva de radiación de cada paciente.

RESULTADOS: La edad promedio fue de 63.2 años. Con una probabilidad pre-test intermedia-baja para enfermedad coronaria en más del 94 % de los pacientes, de los cuales el promedio de dosis de radiación efectiva en angiotomografia coronaria multidetector es de 13.0276 mSv (0.9002 – 20.657).

CONCLUSION: Se trata del primer estudio en el medio donde investiga la dosis de radiación utilizada en angiotomografia coronaria multidetector permitiendo conocer la media de dosis efectiva y así optimizar la misma mediante técnicas de reducción.

ABSTRACT

INTRODUCTION:  The conventional coronography continues to be the standard used to quantify and manage the treatment of coronary disease. However, with the introduction of the multidetector coronary angiothomography in the evaluation of coronary atheromatous plaque, the exposure to radiation has continued to be an area of constant concern. It is recommended that in daily practice the As Low as Reasonably Achievable guidelines be used, which means optimizing the amount of radiation without affecting the quality of the study.

METHOD: This a descriptive retrospective study that took place at the Hospital of specialties José Carrasco Arteaga in Cuenca – Ecuador, covering the time period between January 1, 2013 and December 31, 2015.  The clinical data and effective dose of radiation of each patient who underwent a multidetector coronary angiothomography during this time span were included in the study. 

RESULTS: The average age was 63.2 years, with a low to intermediate pre-test probability of coronary disease in over 94 % of the patients. The average dose of effective radiation in multidetector coronary angiothomography was of 13.0276 mSv (0.9002-20.657).

CONCLUSIONS: This is the first study in our area where the dose of radiation used in multidetector coronary angiothomography has been investigated, making it possible to identify the effective half dose, in this way optimizing the same through the use of reduction techniques.

Biografía del autor/a

Carlos Ismael Ortega Díaz, Hospital de Especialidades José Carrasco Arteaga

Médico Especialista en Cardiología. Hospital de Especialidades José Carrasco Arteaga. Docente de la Universidad de Cuenca. Cuenca, Azuay – Ecuador. ORCID: http://orcid.org/0000-0001-6698-8689

Juan Felipe Vintimilla Garate, Hospital de Especialidades José Carrasco Arteaga

Médico Especialista en Cardiología. Hospital de Especialidades José Carrasco Arteaga. Docente de la Universidad del Azuay. Cuenca, Azuay – Ecuador. 

Arturo Ricardo Quizhpe Rivera, Hospital de Especialidades José Carrasco Arteaga

Médico Cardiólogo Hemodinamista - Intervencionista del Servicio de Hemodinámica del Hospital José Carrasco Arteaga. Clínica Santa Inés.

Winston Xavier Moreira Vera, Hospital de Especialidades José Carrasco Arteaga

Medico Cardiólogo Hemodinamista. Hospital de Especialidades José Carrasco Arteaga. Cuenca, Azuay – Ecuador. 

María José García Zambrano, Hospital de Especialidades José Carrasco Arteaga

Residente asistencial. Hospital de Especialidades José Carrasco Arteaga. Cuenca, Azuay – Ecuador. 

Byron Rafael Coronel Cárdenas, Hospital de Especialidades José Carrasco Arteaga

Residente Asistencial. Hospital de Especialidades José Carrasco Arteaga. Cuenca, Azuay – Ecuador.

Priscila Raquel Criollo Esquivel, Ministerio de Salud Pública del Ecuador

Médico Rural. Ministerio de Salud Pública. Troncal, Cañar – Ecuador.  

Xavier Miguel Salazar Alvarado, Hospital Monte Sinaí

Licenciado en Imagenología. Hospital Monte Sinaí. Cuenca, Azuay – Ecuador. 

Descargas

Publicado

2017-07-28

Cómo citar

1.
Ortega Díaz CI, Vintimilla Garate JF, Quizhpe Rivera AR, Moreira Vera WX, García Zambrano MJ, Coronel Cárdenas BR, Criollo Esquivel PR, Salazar Alvarado XM. Estudio Descriptivo: Dosis Efectiva de Radiación en Angiotomografías Coronarias Multidetector de Enero del 2013 a Diciembre del 2015 en el Hospital de Especialidades José Carrasco Arteaga. HJCA [Internet]. 28 de julio de 2017 [citado 24 de enero de 2025];9(2):134-8. Disponible en: https://revistamedicahjca.iess.gob.ec/ojs/index.php/HJCA/article/view/200

Número

Sección

Trabajos originales